C01065 | l_switchpoint_1: running time, C01066 | l_switchpoint_1: status, 17 parameter reference – Lenze 8400 TopLine User Manual

Page 1151

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1151

17

Parameter reference

17.2

Parameter list | C01065

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01065

C01066

Parameter | Name:

C01065 | L_SwitchPoint_1: Running time

Data type: UNSIGNED_16

Index: 23510

d

= 5BD6

h

From version 02.00.00

Setting range

(min. value | unit | max. value)

0

ms

60000

Subcodes

Lenze setting

Info

C01065/1

0 ms

L_SwitchPoint_1

: Running time 1

C01065/2

0 ms

L_SwitchPoint_1

: Running time 2

C01065/3

0 ms

L_SwitchPoint_1

: Running time 3

C01065/4

0 ms

L_SwitchPoint_1

: Running time 4

C01065/5

0 ms

L_SwitchPoint_1

: Running time 5

C01065/6

0 ms

L_SwitchPoint_1

: Running time 6

C01065/7

0 ms

L_SwitchPoint_1

: Running time 7

C01065/8

0 ms

L_SwitchPoint_1

: Running time 8

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01066 | L_SwitchPoint_1: Status

Data type: INTEGER_16

Index: 23509

d

= 5BD5

h

From version 02.00.00

Selection list

0 OK

10 FB not active

100 Switching points not plausible

Subcodes

Info

C01066/1

L_SwitchPoint_1

: Status 1

C01066/2

L_SwitchPoint_1

: Status 2

C01066/3

L_SwitchPoint_1

: Status 3

C01066/4

L_SwitchPoint_1

: Status 4

C01066/5

L_SwitchPoint_1

: Status 5

C01066/6

L_SwitchPoint_1

: Status 6

C01066/7

L_SwitchPoint_1

: Status 7

C01066/8

L_SwitchPoint_1

: Status 8

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising