19.1.160
L_SignalMonitor_b
This FB outputs four binary signals which can be selected from a list of binary output signals of all
function blocks provided in the device.
• Inversion of the output signals can be set.
Outputs
Parameter
Identifier
Data type
Value/meaning
bOut1
...
bOut4
BOOL
Output signal
FALSE / TRUE
Parameter
Possible settings
Info
...
selection list - digital signals
Selection of the signal sources for
bOut1 ... bOut4
Value is bit-coded:
Inversion
• Bit set = inversion active
Bit 0
bOut1 inverted
Bit 1
bOut2 inverted
Bit 2
bOut3 inverted
Bit 3
bOut4 inverted
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved