19 function library – Lenze 8400 TopLine User Manual

Page 1486

Advertising
background image

19

Function library

19.1

Function blocks

1486

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Tensile force profile according to characteristic
The characteristic () can be parameterised in

C01033/1...32

.

• The characteristic comprises 32 values, regularly distributed over the diameter range of

D0 ... DMax.

• The values are to be set as raw values (±16384 ≡ ±100 %).

nD0_a serves to define the start of the table range (D0).
nCurveCtrl_a serves to change the slope of the characteristic.

• When nCurveCtrl_a = 0 %, the slope of the characteristic remains unchanged.

Tensile force profile according to defined characteristic (

C01035/3

= 6)

Characteristic

Tensile force

Diameter

Function for D > D0:

Table function (e.g. line)

TAB[D-

D0]

Table value [1...32]for D-D0

D0 Starting point for diameter dependency (nD0_a)

HW Tensile force evaluation (nCurveCtrl_a)

Œ



DMin

(DMax)

D0

100 %

100 %

0 %

100 %

nCurveCtrl_a = 0 %

HW

TAB[1]

TAB[32]

0

100 %

100 % TAB[D-D0]

(

) 100 % HW

(

)

100 %

-----------------------------------------------------------------------------------------------

Advertising