Sd9: status message hiperface [xx.0123.00028, Sd14: position invalid hiperface [xx.0123.00029, Oc10: maximum current reached [xx.0123.00030 – Lenze 8400 TopLine User Manual

Page 711: Oc17: clamp sets pulse inhibit [xx.0123.00031, Os1: maximum speed limit reached [xx.0123.00032, Oc10, Oc10: maximum current reached, Xx.0123.00030, Xx.0123.00031, Xx.0123.00032

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

711

10

Diagnostics & error management

10.9

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Sd9: Status message Hiperface [xx.0123.00028]

Sd14: Position invalid Hiperface [xx.0123.00029]

oC10: Maximum current reached [xx.0123.00030]

oC17: Clamp sets pulse inhibit [xx.0123.00031]

oS1: Maximum speed limit reached [xx.0123.00032]

Response (Lenze setting printed in bold)

Setting:

C00603/5

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Sd9 is output when the controller has received a

Hiperface encoder error code from the encoder during

initialisation.

• The received error codes are displayed in

C00491/1...4

. The error codes are explained in the

data sheet of the respective encoder.

Eliminating the fault described in the error code.

Afterwards, reinitialising the encoder by a renewed

writing of the encoder type in

C00422

.

Response (Lenze setting printed in bold)

Setting:

C00603/6

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

No standstill of the Hiperface encoder during

initialisation. Hence, the absolute Hiperface track and

the incremental SinCos track cannot be initiated exactly

and the actual position cannot be detected correctly.

Stopping encoder movement. Afterwards reinitialising

the encoder by a renewed writing of the encoder type in

C00422

.

Response (Lenze setting printed in bold)

Setting:

C00609

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device displays that the maximum current has been

reached.

• Check and, if required, correct dimensioning of the

load with regard to the installed device power.

• Check the maximum current settings in

C00022

(Imax in motor mode) and

C00023

(Imax in generator

mode).

Response (Lenze setting printed in bold)

Setting:

C00569/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Due to a short overcurrent, the inverter was switched off

for a short time (clamp disconnection).

• Check and, if required, correct dimensioning of the

load with regard to the installed device power.

• Reduce the dynamics of the setpoint change or speed

control.

Response (Lenze setting printed in bold)

Setting:

C00579

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device has recognised that the maximum speed has

been reached.

• Limit setpoint selection to maximum values.

• Adjust set speed limitation (

C00909

) and frequency

limitation (

C00910

).

Advertising