10

Diagnostics & error management

10.9

Error messages of the operating system

722

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

PS04: Par. set Mci invalid [xx.0144.00004]

PS07: Par. memory module invalid [xx.0144.00007]

PS08: Par. device invalid [xx.0144.00008]

PS09: Par. format invalid [xx.0144.00009]

PS10: Memory module binding invalid [xx.0144.00010]

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The parameter set saved to the communication module

is incompatible to the standard device.

• An incompatibility of the parameter set is caused e.g.

when the MCI module parameters in the memory

module do not match the plugged communication

module.

When the memory modules are exchanged, observe the

downward compatibility:

• OK: StateLine V2.0 to StateLine V3.0

• OK: StateLine V2.0 to HighLine V2.0

• Not OK: HighLine Vx.x to StateLine Vx.x

• Not OK: StateLine V3.0 to StateLine < V3.0

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The parameter set saved to the memory module is

invalid.

• The error occurs while loading the parameter set.

• The memory module plugged in the device lacks a

code or a code is incorrect.

Consultation with Lenze required.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The parameter set in the device is invalid.

• The error occurs while loading the parameter set.

• One code in the device is incorrect.

Consultation with Lenze required.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The code format is invalid.

• The error occurs while loading the parameter set.

Consultation with Lenze required.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device personalisation is active: The binding ID of the

memory module does not comply with the binding ID of

the controller.

• Use memory module/controller with matching

binding IDs.

• Contact machine manufacturer.

Note:

It is not possible for Lenze to modify a replacement

device via special accesses in such a way that it

cooperates with a personalised memory module.