Parameter | Name:

C01353 | ACDrive: Setpoint scaling

Data type: INTEGER_8

Index: 23222

d

= 5AB6

h

From version 13.00.00

Actuating drive speed (AC Drive Profil): Scaling of the speed and torque values

Setting range

(min. value | unit | max. value)

-128

127

Subcodes

Lenze setting

Info

C01353/1

0

ACDrive: Speed scaling

C01353/2

0

ACDrive: Torque scaling

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01400 | L_Sequencer_1: Sequence step

Data type: UNSIGNED_16

Index: 23175

d

= 5A87

h

From version 12.00.00

In the subcodes, the calls of the actions required for the positioning program are stored. In this way, the basic

sequence (with the exception of the branches) is defined.

L_Sequencer_1 (sequence control)

Setting range

(min. value | unit | max. value)

0

10005

Subcodes

Lenze setting

Info

C01400/1

0

L_Sequencer_1

: Action in sequence step 1

C01400/...

...

C01400/100

L_Sequencer_1

: Action in sequence step 100

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01401 | L_Sequencer_1: Current step

Data type: UNSIGNED_16

Index: 23174

d

= 5A86

h

From version 12.00.00

L_Sequencer_1 (sequence control)

Display range

(min. value | unit | max. value)

0

100

Subcodes

Info

C01401/1

L_Sequencer_1

: Current step

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1