1017

17

Parameter reference

17.2

Parameter list | C00594

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00594

Parameter | Name:

C00594 | Resp. to control word error

Data type: UNSIGNED_8

Index: 23981

d

= 5DAD

h

Configuration of device control monitoring
Selection list

0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
5 Warning

Subcodes

Lenze setting

Info

C00594/1

1: Fault

Response if error bit 14 in the CAN control word is set.

C00594/2

1: Fault

Response if error bit 14 in the MCI control word is set.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1