C01158

C01190

Parameter | Name:

C01158 | L_SwitchPointPar_1: Invert

Data type: UNSIGNED_16

Index: 23417

d

= 5B79

h

From version 12.00.00

Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Invert Output1

Bit set = inversion active

Bit 1 Invert Output2
Bit 2 Invert Output3
Bit 3 Invert Output4
Bit 4 Invert Output5
Bit 5 Invert Output6
Bit 6 Invert Output7
Bit 7 Invert Output8
Bit 8

Reserved

Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved

Subcodes

Lenze setting

Info

C01158/1

0x0000

L_SwitchPointPar_1

: Inversion of outputs

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C01190 | Motor thermal sensor

Data type: UNSIGNED_8

Index: 23385

d

= 5B59

h

Selection of the thermal sensor for monitoring the motor temperature

Encoder/feedback system: Motor temperature monitoring (KTY)

Selection list

Info

0 KTY83-110

Lenze standard KTY83-110 (MDSKX, MCS06)

1 Spec. characteristic

Characteristic defined via

C01191

and

C01192

2 KTY83-110 + 2 x PTC

Lenze standard KTY83-110 + 2 x PTC 150°C (MCS09-

MCS19)

4 KTY84-130

Lenze standard KTY83-130

Subcodes

Lenze setting

Info

C01190/1

0: KTY83-110

Type of motor temperature sensor resolver

C01190/2

0: KTY83-110

Type of motor temperature sensor MultiEncoder

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT