Parameter list | C01069

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01069

C01070

C01071

C01072

Parameter | Name:

C01069 | L_DFSET_1: Ramp settings

Data type: UNSIGNED_16

Index: 23506

d

= 5BD2

h

From version 02.00.00

Setting range

(min. value | unit | max. value)

0

Incr./ms

32767

Subcodes

Lenze setting

Info

C01069/1

10 incr./ms

L_DFSET_1

: Ramp SpeedTrim (1/100)

From version 12.00.00 onwards

, this setting has a

resolution increased by the factor 100: A value of

32767 is internally evaluated with 327.67. Hence, the

unit is [incr./100 ms].

C01069/2

100 incr./ms

L_DFSET_1

: Ramp angle compensation

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01070 | L_DFSET_1: Angular trimming

Data type: INTEGER_32

Index: 23505

d

= 5BD1

h

From version 02.00.00

Setting range

(min. value | unit | max. value)

-134217728

Incr.

134217728

Subcodes

Lenze setting

Info

C01070/1

0 incr.

L_DFSET_1

: Speed-dependent angle adjustment

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01071 | L_DFSET_1: Following error limit

Data type: UNSIGNED_32

Index: 23504

d

= 5BD0

h

From version 02.00.00

Setting range

(min. value | unit | max. value)

10

Incr.

2147483647

Subcodes

Lenze setting

Info

C01071/1

32768 incr.

L_DFSET_1

: Following error limit

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01072 | L_DFSET_1: Multiplier - angular trimming

Data type: INTEGER_16

Index: 23503

d

= 5BCF

h

From version 02.00.00

Setting range

(min. value | unit | max. value)

-20000

20000

Subcodes

Lenze setting

Info

C01072/1

1

L_DFSET_1

: Multiplier - angular trimming

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1