17

Parameter reference

17.2

Parameter list | C00428

974

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00428

C00430

Parameter | Name:

C00428 | SSI encoder: Coding

Data type: UNSIGNED_8

Index: 24147

d

= 5E53

h

Encoder/feedback system: SSI encoder

Selection list

(Lenze setting printed in bold)

Info

0 Binary code
1 Gray code
2 Position Gray

From version 14.00.00

, SSI encoders are supported which

transmit the position data with Gray coding and the

status bits in binary format.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00430 | LS_MultiEncoder: Max. initialization time

Data type: UNSIGNED_16

Index: 24145

d

= 5E51

h

From version 12.00.00

Encoder/feedback system: sin/cos absolute value encoder with HIPERFACE® protocol

Setting range

(min. value | unit | max. value)

500

ms

20000

Subcodes

Lenze setting

Info

C00430/1

1500 ms

Maximum time required by the encoder to respond to

the read request of the controller.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1