C00190 | l_nset_1: setpoint arithmetic, C00191 | logbook access index user, C00192 | logbook data user – Lenze 8400 TopLine User Manual

Page 935: C00190, Nadd" in, To "1, C00191/1, C00192/1, Ested, Dex in

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

935

17

Parameter reference

17.2

Parameter list | C00190

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00190

C00191

C00192

Parameter | Name:

C00190 | L_NSet_1: Setpoint arithmetic

Data type: UNSIGNED_8

Index: 24385

d

= 5F41

h

The

L_NSet_1

FB: Selection of arithmetics

• To be able to influence the main setpoint (NSet) by an additional setpoint (NAdd).

Selection list

(Lenze setting printed in bold)

0 Out = Set
1 Out = Set + Add
2 NOut = NSet - NAdd
3 NOut = (NSet * NAdd) / 100%
4 NOut = (NSet * 1%) / |NAdd|
5 Out = (Set*100%)/(100%-Add)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00191 | Logbook access index User

Data type: UNSIGNED_8

Index: 24384

d

= 5F40

h

From version 12.00.00

Logbook read interface

Setting range

(min. value | unit | max. value)

0

255

Subcodes

Lenze setting

Info

C00191/1

255

Logbook access index User

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00192 | Logbook data User

Data type: OCTET_STRING

Index: 24383

d

= 5F3F

h

From version 12.00.00

Logbook read interface

Display range

(min. value | unit | max. value)

Subcodes

Info

C00192/1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT