Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13.1

Process data transfer

The process data serve to control the controller. Thus the transfer of the process data is time-critical.

• The process cycle is 1 ms, irrespective of the respectively plugged-in bus system and the type of

drive controller.

• Process data transfer takes place cyclically between the master system and the drive controllers.

• This concerns the continuous exchange of current input and output data.
• In the case of the 8400 drive controller, 16 words per direction are exchanged.

• The master computer can directly access the process data.

Access to the process data takes place via the port blocks LP_MciIn and LP_MciOut (see FB

interconnection of the »Engineer«).

These port blocks are also called process data channels.

• The process data are not saved in the controller.

[13-1] External and internal data transfer between bus system, drive controller and function block interconnection