2 open-circuit monitoring htl encoder, Open-circuit monitoring htl encoder, 6encoder/feedback system – Lenze 8400 TopLine User Manual

Page 370

Advertising
background image

6

Encoder/feedback system

6.7

Monitoring

370

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.7.2

Open-circuit monitoring HTL encoder

Open-circuit monitoring is available for the HTL encoder cable.

When does the open-circuit monitoring system respond?
The open-circuit monitoring will trigger if

• an open circuit occurs in the encoder cable.
• an extreme overload (e.g. blocked motor shaft) occurs during the start-up phase of the motor.
• highly dynamic reversion of the motor occurs.
• the motor still rotates at high speed in the "SC servo control ASM" mode when the controller

enabled.

Which measured values lead to an actuation of the open-circuit monitoring system?
The following measured values checked for plausibility lead to an actuation of the open-circuit

monitoring system:

1. If the total deviation between actual speed and setpoint speed is higher than f = 40 Hz for a time

> 0.1 s .

2. If the actual speed detected is f = 0 Hz or n = 0 rpm and the I

max

controller or the torque

limitation for servo control (SC) is active for t ≥ 0.1 s.

3. If the sign of the injected frequency and the actual speed is not the same, the I

max

controller is

active and this status is active for 0.1 s. Usually this is the case when A/B tracks are reversed.

Response to open circuit

• If the open-circuit monitoring is tripped:

• The error response set in

C00586

is activated (Lenze setting: "Fault").

• The "

Sd3: Open circuit - feedback system

" is entered into the Logbook.

• The bMctrlEncoderComFault status output of the

LS_DeviceMonitor

SB is set to TRUE.

• A setting of

C00586

= "0: No Reaction" deactivates the monitoring.

Danger!

For safety reasons, always select "Fault" (Lenze setting) as a response for the (open-

circuit) monitoring of the HTL encoder!

Note!

If you do not use an HTL encoder, deactivate the monitoring (

C00586

= "0: No Reaction").