177 l_transient_5, 177 l_transient_5 4, L_transient_5 – Lenze 8400 TopLine User Manual
Page 1694: 19 function library
19
Function library
19.1
Function blocks
1694
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
19.1.177
L_Transient_5
This FB serves to evaluate digital signal edges and convert them into timed, retriggerable pulses.
Rising signal edges, falling signal edges or both signal edges can be evaluated.
Inputs
Outputs
Parameter
Identifier
Data type
Information/possible settings
bIn
BOOL
Input for edge evaluation
• The function depends on the selection of edge evaluation in
Identifier
Data type
Value/meaning
bOut
BOOL
Output (retriggerable)
Parameter
Possible settings
Info
Function
• Selection of edge evaluation
0 High edge
Lenze setting
1 Low edge
2 High and low edge
0.001
s
60.000 Pulse duration
• Lenze setting: 0.001 s
For a detailed functional description see
.
E2XW
E,Q
W
&
&
/B
B
7UDQVLHQW