C01010 | l_arithmetikphi 1-3: function, C01011 | l_arithmetikphi 4-6: function, C01012 | l_phidiv: bydivision – Lenze 8400 TopLine User Manual

Page 1139: 17 parameter reference

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1139

17

Parameter reference

17.2

Parameter list | C01010

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01010

C01011

C01012

Parameter | Name:

C01010 | L_ArithmetikPhi 1-3: Function

Data type: UNSIGNED_8

Index: 23565

d

= 5C0D

h

Selection of the internal arithmetics
Selection list

0 dnOut_p = dnIn1_p
1 dnOut_p = dnIn1_p + dnIn2_p
2 dnOut_p = dnIn1_p - dnIn2_p
3 dnOut_p = dnIn1_p * dnIn2_p
4 dnOut_p = dnIn1_p / dnIn2_p

Subcodes

Lenze setting

Info

C01010/1

0: dnOut_p = dnIn1_p

L_ArithmetikPhi_1

: Function

C01010/2

0: dnOut_p = dnIn1_p

L_ArithmetikPhi_2

: Function

C01010/3

0: dnOut_p = dnIn1_p

L_ArithmetikPhi_3

: Function

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01011 | L_ArithmetikPhi 4-6: Function

Data type: UNSIGNED_8

Index: 23564

d

= 5C0C

h

From version 12.00.00

Selection of the internal arithmetics
Selection list

0 dnOut_p = dnIn1_p
1 dnOut_p = dnIn1_p + dnIn2_p
2 dnOut_p = dnIn1_p - dnIn2_p
3 dnOut_p = dnIn1_p * dnIn2_p
4 dnOut_p = dnIn1_p / dnIn2_p

Subcodes

Lenze setting

Info

C01011/1

0: dnOut_p = dnIn1_p

L_ArithmetikPhi_4

: Function

C01011/2

0: dnOut_p = dnIn1_p

L_ArithmetikPhi_5

: Function

C01011/3

0: dnOut_p = dnIn1_p

L_ArithmetikPhi_6

: Function

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01012 | L_PhiDiv: byDivision

Data type: INTEGER_8

Index: 23563

d

= 5C0B

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

-31

31

Subcodes

Lenze setting

Info

C01012/1

0

L_PhiDiv_1

: byDivision

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising