19

Function library

19.2

System blocks

1704

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

19.2.14.1 Display of internal process variables in application units

In addition to the display in percent in

C00482/1...8

, for the first four analog signals

nDis1_a ... nDis4_a the configurable display parameters

C00487/1...4

are provided. Via these

display parameters, internal process variables can be displayed, e.g. on the keypad, with an

individual scaling and an individual unit (from keypad version 02.01).

Configuration of the display parameters (

C00487/1...4

):

[19-81] Formula for scaling the display

Example 1:

• Input variable nDis1_a = 100 %
• Offset 1 (

C00484/1

) = 0 %

• Display factor 1 (

C00485/1

) = 123.45

• Text 1 (

C00486/1

) = "parts"

Example 2:

• Input variable nDis2_a = 40 %
• Offset 2 (

C00484/2

) = 35 %

• Display factor 2 (

C00485/2

) = 20

• Text 2 (

C00486/2

) = "kg"

Parameter

Possible settings

Info

C00484/1...4

-199.99

%

199.99 Offset 1 ... 4

• See formula

[19-81]

.

• Lenze setting: 0.00 %

C00485/1...4

-65536.0000

65536.0000 Display factor 1 ... 4

• Scaling of the input variable for

the display.

• See formula

[19-81]

.

• Lenze setting: 1.0000

C00486/1...4

String of digits

(max. 7 digits)

Text 1 ... 4

• For each display value, an

individual unit (e.g. "parts") can be

set.

User unit 1

nDis1_a [%] Offset 1 [%]

+

100 [%]

--------------------------------------------------------------------

Display factor 1 [text 1]

=

User unit 1

100 [%] 0 [%]

+

100 [%]

---------------------------------------

123.45 [parts]

123.45 parts

=

=

User unit 2

40 [%] 35 [%]

+

100 [%]

---------------------------------------

20 [kg]

15.00 kg

=

=