1 set machine parameters, Set machine parameters, 3commissioning – Lenze 8400 TopLine User Manual

Page 73

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

73

3

Commissioning

3.8

Commissioning of the "Table positioning" technology application

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.8.4.1

Set machine parameters

1. Go to the right side of the Application parameter tab and click the Machine parameter button

to change to the OverviewMachine parameter dialog level:

2. Set the machine parameters according to the system constellation at hand.

Note!

Setting the machine parameters is a basic prerequisite for the operating modes

"

Homing

", "

Manual jog

" and "

Positioning

".

The more precisely the machine parameters are set, the better the results of positioning!
Detailed information on the machine parameters is provided in chapter "Basic drive

functions" in subchapter "

Machine parameters

".

( 582)

Parameter

Lenze setting

Info

Value Unit

Mounting direction: Motor

(

C01206/1

)

not inverted

Inversion if motor mounting is mirrored.

Numerator (Z2)

(

C01202/1

)

1

Gearbox factor - motor

• Entry of the gearbox factor as

numerator/denominator ratio (numerator = motor

speed and denominator = output speed of gearbox)

or from the number of teeth of the gearbox

arrangement.

Denominator (Z1)

(

C01202/2

)

1

Mounting direction: Position

encoder

(

C01206/2

)

not inverted

Inversion if position encoder mounting is mirrored.

Counter

(

C01203/1

)

1

Gearbox factor - position encoder

• Entry of the gearbox factor as

numerator/denominator ratio, with numerator =

motor speed and denominator = position encoder

speed.

Denominator

(

C01203/2

)

1

Advertising