6 homing, Homing, Homing ( 606) – Lenze 8400 TopLine User Manual

Page 606: Mode, 9basic drive functions (mck), Danger

Advertising
background image

9

Basic drive functions (MCK)

9.6

Homing

606

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.6

Homing

The measuring system in the machine is selected by means of homing and the 0 position is set

within the possible physical travel range:

[9-24] Homing (selection of 0 position)

The zero position (home) can be defined by a reference run or by setting a home position:

• If a reference run is carried out, the drive follows a previously selected path to find the home

position.

• When the reference is set, it is selected manually when the drive stands still.

Tip!
A reference run is mainly used for systems with feedback via encoders, resolvers, or single-

turn absolute value encoders, as in the case of these systems the home position is lost

when the supply voltage is switched off.
Usually the reference is set only once during commissioning or in the event of service (e. g.

if drive components are replaced), and it is mostly used for systems with feedback via

absolute value encoders.

0-Position

10

20

30

40

50

60

-10

Danger!

During homing operations, specially assigned profile parameters are effective. If these

parameters are not set correctly, the drive may execute unexpected movements!

Advertising