151 l_pt1_2, 151 l_pt1_2 9, L_pt1_2 – Lenze 8400 TopLine User Manual
Page 1639: 19 function library
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1639
19
Function library
19.1
Function blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
19.1.151
L_PT1_2
This FB filters and delays analog signals.
• Filter time constant T can be set in
• The gain is defined with V
p
= 1.
Inputs
Outputs
Parameter
Function
[19-67] Filter time constant T of the first-order delay element
Identifier
Data type
Information/possible settings
nIn_a
INT
Input signal
Identifier
Data type
Value/meaning
nOut
INT
Output signal
Parameter
Possible settings
Info
0
ms
5000 Filter time constant
• The filter is not active with a
setting of "0 ms". The input signal
is passed through one-to-one to
the output.
• Lenze setting: 2000 ms
/B37B
)LOWHUWLPH
&
Q,QBD
Q2XWBD
T
V = 1
p
t