Parameter reference

17.2

Parameter list | C01407

1208

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01407

C01408

C01409

Parameter | Name:

C01407 | L_Sequencer_1: PSProfil

Data type: UNSIGNED_16

Index: 23168

d

= 5A80

h

From version 12.00.00

L_Sequencer_1: "Positioning" action

Setting range

(min. value | unit | max. value)

0

15

Subcodes

Lenze setting

Info

C01407/1

0

L_Sequencer_1

: Pos. action 1: Profile number

C01407/...

...

C01407/50

L_Sequencer_1

: Pos. action 50: Profile number

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01408 | L_Sequencer_1: PSStep

Data type: UNSIGNED_16

Index: 23167

d

= 5A7F

h

From version 12.00.00

L_Sequencer_1: "Positioning" action

Setting range

(min. value | unit | max. value)

0

100

Subcodes

Lenze setting

Info

C01408/1

0

L_Sequencer_1

: Pos. action 1: Jump destination

C01408/...

...

C01408/50

L_Sequencer_1

: Pos. action 50: Jump destination

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01409 | L_Sequencer_1: PS_WD_Time

Data type: UNSIGNED_32

Index: 23166

d

= 5A7E

h

From version 12.00.00

L_Sequencer_1: "Positioning" action

Setting range

(min. value | unit | max. value)

0.000

2147480.000

Subcodes

Lenze setting

Info

C01409/1

0.000

L_Sequencer_1

: Pos. action 1: Monitoring time

C01409/...

...

C01409/50

L_Sequencer_1

: Pos. action 50: Monitoring time

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000