14 axis bus – Lenze 8400 TopLine User Manual

Page 850

Advertising
background image

14

Axis bus

14.2

Data transfer axis bus

850

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

Related topics:

Configuring exception handling of the received data

( 844)

bStop

BOOL

Stop data transfer

TRUE The axis bus changes to the "Stopped" state.

• The slaves neither accept any data nor send any data anymore.

• The master continues to send the line data.

• The bit 2 ("NodeStopped") in

C02442/1

serves to set whether the

last received data remain active or the decoupling values are set.

Configuring exception handling of the received data

Output

Data type

Value/meaning

wAuxIn1/wAuxIn2

WORD

Received data - word 1 and word 2

dnAuxIn12

DINT

Received data - word 1 and word 2 as double word

wAuxIn3/wAuxIn4

WORD

Received data - word 3 and word 4

dnAuxIn34

DINT

Received data - word 3 and word 4 as double word

wSlaveNo

WORD

Display which slave has sent its data.

• Output only relevant for master.

bDone

BOOL

Status signal "Data transfer completed"

FALSE The master has sent a new read request to a slave.

TRUE Data has been received correctly.

bFail

BOOL

Status signal "Fault"

TRUE Data has not been received correctly (e.g. bus error).

Axis bus data error monitoring

Input

Data type

Information/possible settings