Parameter list | C02867

1288

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02867

C02870

C02871

Parameter | Name:

C02867 - Identification procedure

Data type: UNSIGNED_8

Index: 21708

d

= 54CC

h

Selection of the identification procedure for motor parameter identification

Automatic motor parameter identification

Selection list

Info

0 automatic

Automatic selection of the optimum identification

procedure:

• For synchronous motors, the extended identification

procedure is always used.

• For asynchronous motors with a rated motor power

of up to 11 kW, the basic identification procedure is

used.

• For asynchronous motors with a rated motor power

of more than 11 kW, the extended identification

procedure is used.

1 standard identification

• Only for asynchronous motors.

• Duration approx. 30 s

2 extended identification

• Stands out due to increased accuracy of the

determined motor parameters.

• Also supports synchronous motors and asynchronous

motors with a power of more than 11 kW.

• Duration approx. 80 s

Subcodes

Lenze setting

Info

C02867/1

0: automatic

Motor parameter identification: Process

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02870 | PLI without motion: Optimisation factor

Data type: INTEGER_16

Index: 21705

d

= 54C9

h

From version 02.00.00

Pole position identification without motion

Display range

(min. value | unit | max. value)

0.00

%

300.00

Subcodes

Info

C02870/1

PLI without motion: Optimisation factor

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02871 | PLI without motion: Running time

Data type: INTEGER_16

Index: 21704

d

= 54C8

h

From version 02.00.00

Pole position identification without motion

Display range

(min. value | unit | max. value)

0.00

ms

300.00

Subcodes

Info

C02871/1

PLI without motion: Running time

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100