C01470 | l_mfail: tn, C01501 | resp. to communication error with mci, C01501/1 – Lenze 8400 TopLine User Manual

Page 1228: C01501/2, 17 parameter reference

Advertising
background image

17

Parameter reference

17.2

Parameter list | C01470

1228

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01470

C01501

Parameter | Name:

C01470 | L_MFail: Tn

Data type: UNSIGNED_16

Index: 23105

d

= 5A41

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

1

ms

60000

Subcodes

Lenze setting

Info

C01470/1

20 ms

L_MFail_1

: U DC-bus controller reset time

C01470/2

20 ms

L_MFail_1

: Acceleration time

C01470/3

20 ms

L_MFail_1

: Retrigger time

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01501 | Resp. to communication error with MCI

Data type: UNSIGNED_8

Index: 23074

d

= 5A22

h

Configuration of monitoring functions for the communication module
Selection list

0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information

Subcodes

Lenze setting

Info

C01501/1

0: No Reaction

Resp. to MCI connection error

• Response to a communication error of the attached

communication module.

C01501/2

0: No Reaction

Resp. to MCI invalid module

• Response to an unplugged or incompatible

communication module

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising