Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1165

17

Parameter reference

17.2

Parameter list | C01119

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01119

C01120

C01121

Parameter | Name:

C01119 | LS_MultiEncoder: Current position

Data type: INTEGER_32

Index: 23456

d

= 5BA0

h

From version 02.00.00

Encoder/feedback system: Multi-Encoder

Display range

(min. value | unit | max. value)

-214748.3647

units

214748.3647

Subcodes

Info

C01119/1

LS_MultiEncoder

: Current position

C01119/2

LS_MultiEncoder

: Maximum travel distance

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01120 | Sync signal source

Data type: UNSIGNED_8

Index: 23455

d

= 5B9F

h

Selection of the signal source for device synchronisation

• The drive can only be synchronised by one source.

Synchronisation of the internal time base

Selection list

(Lenze setting printed in bold)

Info

0 Off

Synchronisation off

1 CAN on board

Synchronisation via CAN bus

Sync telegram

2 AxisBusIO

Synchronisation via axis bus

Axis bus

4 MCI

Synchronisation via MCI (communication module)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01121 | Sync cycle time setpoint

Data type: UNSIGNED_16

Index: 23454

d

= 5B9E

h

Cycle time setpoint for device synchronisation

• Time interval at which the phase control loop (PLL) in the controller expects the synchronisation signals.

• The cycle time setpoint must be set according to the cycle of the respective synchronisation source.

Note:

• Only integer multiples of 1000 μs can be set.

• Intelligent communication modules usually define the cycle time setpoint derived from the bus cycle. In this

case, a manual change is not possible.

Example: For the CAN bus, a distance of 2 ms has been set between two synchronisation signals. If the CAN bus is

to be used as synchronisation source, a synchronisation cycle of 2000 μs must be set in C01121.

Synchronisation of the internal time base

Setting range

(min. value | unit | max. value)

Lenze setting

1000

μs

20000 1000 μs

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT