19

Function library

19.1

Function blocks

1650

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

General parameters

Note!

The parameters of the different actions for the sequence table are described in the

corresponding action subchapter.

Parameter

Possible settings

Info

C01400/1...100

Action in sequence step n

• In the subcodes, the calls of the

actions required for the

positioning program are stored. In

this way, the basic sequence (with

the exception of the branches) is

defined.

0 Program end

xxyyy Action call

• xx ≡ Action type

• yyy ≡ Action number

C01401

1

100 Current step

• Read only

C01402

Sequence control: Status

• Read only

0 READY: Positioning program ready

to start/program end reached.

1 RUN: Positioning program is

running.

2 PAUSE: Current step interrupted,

break is active.

3 BREAK: Positioning program

interrupted.

4 RESET: Positioning program reset.

C01403

Sequence control: Control word

• Bit coded code for controlling the

sequencer by a PC or a master

control via parameter channel.

• By setting a bit to "1", the

respective function is activated.

Bit 0 Start
Bit 1 Break
Bit 2 Break
Bit 3 Cancel
Bit 4 Reset
Bit 5 NextStep

C01404

Step takes place when bCancel =

TRUE

• This step is processed if the

bCancel input is set to TRUE.

0 Sequence step

1...100 Step 1 ... 100

101 Program end