C01419 | l_sequencer_1: branchstep2, C01420 | l_sequencer_1: branchstep3, C01421 | l_sequencer_1: branchstep4 – Lenze 8400 TopLine User Manual

Page 1213: C01422 | l_sequencer_1: branchstep5, 17 parameter reference

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1213

17

Parameter reference

17.2

Parameter list | C01419

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01419

C01420

C01421

C01422

Parameter | Name:

C01419 | L_Sequencer_1: BranchStep2

Data type: UNSIGNED_16

Index: 23156

d

= 5A74

h

From version 12.00.00

L_Sequencer_1: "Variable branch" action

Setting range

(min. value | unit | max. value)

0

100

Subcodes

Lenze setting

Info

C01419/1

0

L_Sequencer_1

: Var. branch 1: Jump destin. 2

C01419/2

0

L_Sequencer_1

: Var. branch 2: Jump destin. 2

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01420 | L_Sequencer_1: BranchStep3

Data type: UNSIGNED_16

Index: 23155

d

= 5A73

h

From version 12.00.00

L_Sequencer_1: "Variable branch" action

Setting range

(min. value | unit | max. value)

0

100

Subcodes

Lenze setting

Info

C01420/1

0

L_Sequencer_1

: Var. branch 1: Jump destin. 3

C01420/2

0

L_Sequencer_1

: Var. branch 2: Jump destin. 3

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01421 | L_Sequencer_1: BranchStep4

Data type: UNSIGNED_16

Index: 23154

d

= 5A72

h

From version 12.00.00

L_Sequencer_1: "Variable branch" action

Setting range

(min. value | unit | max. value)

0

100

Subcodes

Lenze setting

Info

C01421/1

0

L_Sequencer_1

: Var. branch1: Jump destin. 4

C01421/2

0

L_Sequencer_1

: Var. branch 2: Jump destin. 4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01422 | L_Sequencer_1: BranchStep5

Data type: UNSIGNED_16

Index: 23153

d

= 5A71

h

From version 12.00.00

L_Sequencer_1: "Variable branch" action

Setting range

(min. value | unit | max. value)

0

100

Subcodes

Lenze setting

Info

C01422/1

0

L_Sequencer_1

: Var. branch 1: Jump destin. 5

C01422/2

0

L_Sequencer_1

: Var. branch 2: Jump destin. 5

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising