C00441 | decoupling analogout, C00442 | aoutx: decoupling value, Carried out in – Lenze 8400 TopLine User Manual

Page 979: C00441, C00442/1, C00442/2, C00442/3, C00442/4, 17 parameter reference

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

979

17

Parameter reference

17.2

Parameter list | C00441

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00441

C00442

Parameter | Name:

C00441 | Decoupling AnalogOut

Data type: UNSIGNED_16

Index: 24134

d

= 5E46

h

Configuration defining the events that lead to a decoupling of the analog output terminals.

Configuring exception handling of the output terminals

Setting range

(min. hex value | max. hex value)

Lenze setting

0x0000

0xFFFF 0x0000 (decimal: 0)

Value is bit-coded: (= bit set)

Bit 0  SafeTorqueOff
Bit 1  ReadyToSwitchOn
Bit 2  SwitchedOn
Bit 3 

Reserved

Bit 4  Trouble
Bit 5  Fault
Bit 6 

Reserved

Bit 7 

Reserved

Bit 8 

Reserved

Bit 9  Fail CAN_Management

Bit 10 

Reserved

Bit 11 

Reserved

Bit 12 

Reserved

Bit 13 

Reserved

Bit 14 

Reserved

Bit 15 

Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00442 | AOutx: Decoupling value

Data type: INTEGER_16

Index: 24133

d

= 5E45

h

Definition of the value the analog output terminals are to have in the decoupled state.

Configuring exception handling of the output terminals

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C00442/1

0.00 %

AOut1_U: Decoupling value

C00442/2

0.00 %

AOut2_U: Decoupling value

C00442/3

0.00 %

AOut1_I: Decoupling value

C00442/4

0.00 %

AOut2_I: Decoupling value

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100