2 function 2: nin1 > nin2, Function 2: nin1 > nin2 6, 19 function library – Lenze 8400 TopLine User Manual

Page 1416

Advertising
background image

19

Function library

19.1

Function blocks

1416

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

19.1.26.2 Function 2: nIn1 > nIn2

This function serves, for instance, to implement the comparison "actual speed is higher than a limit

value" (n

act

> n

x

) for one direction of rotation.

[19-8] Function 2: Switching performance

Functional sequence

1. If the value at nIn1_a exceeds the value nIn2_a, bOut changes from FALSE to TRUE.
2. Only if the signal at nIn1_a falls below the value of nIn2_a - hysteresis again, bOut changes back

from TRUE to FALSE.

[19-9] Function 2: Example

C00681

: Hysteresis

TRUE

FALSE

bOut

nIn2_a

nIn1_a

Œ

C00681

: Hysteresis

nIn1_a

nIn2_a

TRUE

FALSE

bOut

t

t

Œ