19.1.26.2 Function 2: nIn1 > nIn2
This function serves, for instance, to implement the comparison "actual speed is higher than a limit
value" (n
act
> n
x
) for one direction of rotation.
[19-8] Function 2: Switching performance
Functional sequence
1. If the value at nIn1_a exceeds the value nIn2_a, bOut changes from FALSE to TRUE.
2. Only if the signal at nIn1_a falls below the value of nIn2_a - hysteresis again, bOut changes back
from TRUE to FALSE.
[19-9] Function 2: Example
: Hysteresis
TRUE
FALSE
bOut
nIn2_a
nIn1_a
: Hysteresis
nIn1_a
nIn2_a
TRUE
FALSE
bOut
t
t