5motor control (mctrl) – Lenze 8400 TopLine User Manual

Page 261

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

261

5

Motor control (MCTRL)

5.10

Parameterisable additional functions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

All other types of control require the following settings in addition:

Parameter

Info

Required setting

C00022

Imax in motor mode

higher than rated motor current

(max. 160 % rated motor current)

C00081

Rated motor power

adapt motor data

(see motor nameplate),

then carry out identification run

Automatic motor data

identification ( 141)

C00087

Rated motor speed

C00088

Rated motor current

C00089

Rated motor frequency

C00090

Rated motor voltage

C00091

Motor cos ϕ

Advertising