19.2.34
LS_ParReadWrite_1-6
The LS_ParReadWrite_1 ... LS_ParReadWrite_6 system blocks are used for reading and writing local
parameters.
• If several system blocks are activated at the same time, the blocks will be processed one at a
time every time the main program is executed.
• The SB supports one-time and cyclic reading/writing in an adjustable time interval.
Inputs
Identifier
Data type
Information/possible settings
bExecute
BOOL
Trip read/write request
FALSETRUE If cycle time (C01091) = "0 ms":
One-time reading/writing of the parameter value which has been
addressed via thewParIndex and wParSubindex inputs.
If cycle time (C01091) > "0 ms":
Cyclic reading/writing of the parameter value which has been
addressed via the wParIndex and wParSubindex inputs.
TRUEFALSE Deactivate cyclic reading/writing again.
bReadWrite
BOOL
Selection: Read or write request
FALSE Read request
TRUE Write request
wParIndex
WORD
Code to be read or written.
• The selection can be made alternatively via C01090.
wParSubindex
WORD
Subcode to be read or written.
• The selection can be made alternatively via C01090.
wInHWord
wInLWord
WORD
Value to be written (DataHigh/DataLow portion)