C02830 | dix: debounce time, C02830/1, 17 parameter reference – Lenze 8400 TopLine User Manual
Page 1280
17
Parameter reference
17.2
Parameter list | C02830
1280
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02830
Parameter | Name:
C02830 | DIx: Debounce time
Data type: UNSIGNED_8
Index: 21745
d
= 54F1
h
Debounce times for the digital inputs
Selection list
0 0.00 ms
1 0.25 ms
2 0.50 ms
3 0.75 ms
4 1.00 ms
5 1.25 ms
6 1.50 ms
7 1.75 ms
8 2.00 ms
10 2.50 ms
12 3.00 ms
14 3.50 ms
16 4.00 ms
18 4.50 ms
20 5.00 ms
22 5.50 ms
24 6.00 ms
28 7.00 ms
32 8.00 ms
36 9.00 ms
40 10.0 ms
44 11.0 ms
48 12.0 ms
52 13.0 ms
56 14.0 ms
64 16.0 ms
72 18.0 ms
80 20.0 ms
88 22.0 ms
96 24.0 ms
104 26.0 ms
112 28.0 ms
120 30.0 ms
128 32.0 ms
Subcodes
Lenze setting
Info
C02830/1
1: 0.25 ms
DI1 ... DI7: Debounce time
C02830/...
C02830/7
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1