C02830

Parameter | Name:

C02830 | DIx: Debounce time

Data type: UNSIGNED_8

Index: 21745

d

= 54F1

h

Debounce times for the digital inputs

Digital input terminals

Selection list

0 0.00 ms
1 0.25 ms
2 0.50 ms
3 0.75 ms
4 1.00 ms
5 1.25 ms
6 1.50 ms
7 1.75 ms
8 2.00 ms

10 2.50 ms
12 3.00 ms
14 3.50 ms
16 4.00 ms
18 4.50 ms
20 5.00 ms
22 5.50 ms
24 6.00 ms
28 7.00 ms
32 8.00 ms
36 9.00 ms
40 10.0 ms
44 11.0 ms
48 12.0 ms
52 13.0 ms
56 14.0 ms
64 16.0 ms
72 18.0 ms
80 20.0 ms
88 22.0 ms
96 24.0 ms

104 26.0 ms
112 28.0 ms
120 30.0 ms
128 32.0 ms

Subcodes

Lenze setting

Info

C02830/1

1: 0.25 ms

DI1 ... DI7: Debounce time

C02830/...
C02830/7

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1