C02607 | holding brake: status, C02607, 17 parameter reference – Lenze 8400 TopLine User Manual

Page 1273

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1273

17

Parameter reference

17.2

Parameter list | C02607

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02607

Parameter | Name:

C02607 | Holding brake: Status

Data type: UNSIGNED_16

Index: 21968

d

= 55D0

h

Switching status of the holding brake control

Holding brake control

Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Brake applied

1 ≡ Holding brake is completely closed

Bit 1 Brake released

1 ≡ Holding brake is completely released

Bit 2 Feedforward control active

1 ≡ Feedforward control for holding of the load via the

motor is active before the holding brake releases.

Bit 3 Closing active

1 ≡ The brake closing time (

C02589/1

) expires

Bit 4 Forced release active

1 ≡ In case of automatic operation of the holding brake

control, the brake is directly released via the MCK input

bMBrakeRelease = TRUE

Bit 5 Release active

1 ≡ The brake release time (

C02589/2

) expires

Bit 6 Setpoint synchronisation active

1 ≡ A speed setpoint at the MCK is approached along a

defined ramp after brake release

Bit 7 Signalling contact error

1 ≡ The status monitoring has tripped

Bit 8

Reserved

Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT