C01466 | l_convactpos: tconstvadd, C01467 | l_convactpos: deadband, C01468 | l_convactpos: damping – Lenze 8400 TopLine User Manual

Page 1227: C01469 | l_mfail: vp, 17 parameter reference

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1227

17

Parameter reference

17.2

Parameter list | C01466

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01466

C01467

C01468

C01469

Parameter | Name:

C01466 | L_ConvActPos: TConstVAdd

Data type: UNSIGNED_16

Index: 23109

d

= 5A45

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

0

ms

1000

Subcodes

Lenze setting

Info

C01466/1

10 ms

L_ConvActPos_1

: TConstVAdd

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01467 | L_ConvActPos: DeadBand

Data type: INTEGER_16

Index: 23108

d

= 5A44

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C01467/1

1.00 %

L_ConvActPos_1

: DeadBand

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C01468 | L_ConvActPos: Damping

Data type: UNSIGNED_16

Index: 23107

d

= 5A43

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

0.00

10.00

Subcodes

Lenze setting

Info

C01468/1

0.00

L_ConvActPos_1

: Damping

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C01469 | L_MFail: Vp

Data type: UNSIGNED_16

Index: 23106

d

= 5A42

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

0.001

31.000

Subcodes

Lenze setting

Info

C01469/1

1.000

L_MFail_1

: Vp

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000