82 l_digitallogic_2, 82 l_digitallogic_2 6, L_digitallogic_2 – Lenze 8400 TopLine User Manual

Page 1516: 19 function library

Advertising
background image

19

Function library

19.1

Function blocks

1516

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

19.1.82

L_DigitalLogic_2

This FB provides a binary output signal created by a logic operation of the input signals. Optionally,

one of the constant binary values independent from the input signals can be output.

• Output of a constant binary value
• AND operation of the inputs
• OR operation of the inputs
• Output depending on the combination of the input signals

Inputs

Outputs

Parameter

Identifier

Data type

Information/possible settings

bIn1

BOOL

Input signal 1

bIn2

BOOL

Input signal 2

bIn3

BOOL

Input signal 3

Identifier

Data type

Value/meaning

bOut

BOOL

Output signal

Parameter

Possible settings

Info

C00822

Function selection

0 "0"

Constant value "FALSE"

1 "1"

Constant value "TRUE"

2

AND operation

3

OR operation

4 bOut = f (truth table)

The output value depends on the

truth table parameterised in

C00823/1...8

/B'LJLWDO/RJLFB




!


































E2XW

&

&

&

&

&

E,Q

E,Q

E,Q

bOut

bIn1 bIn2 bIn3

=

bOut

bIn1 bIn2 bIn3

=

Advertising