3.10

PC manual control

90

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.10

PC manual control

For the purpose of testing and demonstration and when an online connection has been established,

the PC manual control enables the manual control of various drive functions from the »Engineer«.

Supported drive functions:

• Speed control (follow speed setpoint)
• Activate/deactivate quick stop
• Set/reset home position
• Manual jog
• Positioning (relative or absolute)

More control functions:

• Reset error message

Set digital/analog outputs (in preparation)

Diagnostic functions:

• Display of the actual speed value and motor current (as time characteristic)
• Display of the current device status
• Display of the status determining error

Display of the status of the digital/analog inputs (in preparation)