10

Diagnostics & error management

10.6

Monitoring

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

10.6

Monitoring

The controller is provided with various monitoring functions which protect the drive against

impermissible operating conditions.

• If a monitoring function responds,

• an entry will be made into the

Logbook

of the controller,

• the response (TroubleQSP, Warning, Fault, etc.) set for this monitoring function will be

triggered,

• the status of the internal device control changes according to the selected response,

controller inhibit is set, and the "DRV- ERR" LED on the front of the controller goes on:

Related topics:

LED status displays of the device status

( 675)

Device state machine and device states

( 113)

Device overload monitoring (Ixt)

( 293)

Motor load monitoring (I2xt)

( 294)

Motor temperature monitoring (PTC)

( 297)

Brake resistor monitoring (I2xt)

( 298)

Motor phase failure monitoring

( 300)

Mains phase failure monitoring

( 303)

Maximum current monitoring

( 303)

Maximum torque monitoring

( 304)

Resolver/multi-encoder open-circuit monitoring

( 369)

Open-circuit monitoring HTL encoder

( 370)

Motor temperature monitoring (KTY)

( 373)

Response

Entry in the

logbook

Display in

C00168

Disable

voltage

Controller

inhibit

Acknowledge

ment

required

"DRV-ERR" LED

None

OFF

Fault

Trouble

TroubleQSP

WarningLocked

Warning

Information

OFF

System fault

Mains

switching

is required!