19.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

19.1.158.11 Action type "Time waiting"

For inserting waiting times into the program flow, 8 actions of "Time waiting" are available. The

sequence step will only be processed after a waiting time has elapsed or when a selectable

sequencer input has a certain bit state ("0" or "1").

Action call (entry in the sequence table)

with action number xxx = 001 ... 008

Parameter
The available actions 1 ... 8 are represented via the subcodes 1 ... 8.

Parameter

Possible settings

Info

C01438/1...8

0.000

s

2127480.000 Waiting act. n: Waiting time

• Initialisation: 1.000 s

C01439/1...8

Waiting act. n: Input for "Next"

0 Input deactivated

"Time waiting": Sequence step will

only be processed after the set

waiting time has elapsed.

1 Sequencer input 1

(Bit 0 of wDigitalInputs)

"Wait for level": Sequence step will

only be processed when the selected

sequencer input has the polarity set

in

C01440/x

.

Note!

With a waiting time set to > 0 s,

however, the sequence step will be

processed after the set waiting time

has elapsed at the latest.

2 Sequencer input 2

(Bit 1 of wDigitalInputs)

... ...

16 Sequencer input 16

(Bit 15 of wDigitalInputs)

C01440/1...8

Waiting act. n: Polarity input

• State of the selected sequencer

input required for processing the

sequence step.

0 Condition is bit state "0"
1 Condition is bit state "1"

7 x x x