Ab01: axis bus timeout [xx.0126.00001, Ab02: axis bus io error [xx.0126.00002, Ce04: mci communication error [xx.0127.00002 – Lenze 8400 TopLine User Manual

Page 718: Ce0f: mci control word [xx.0127.00015, Xx.0126.00001, Xx.0126.00002, Xx.0127.00002, Xx.0127.00015, 10 diagnostics & error management

Advertising
background image

10

Diagnostics & error management

10.9

Error messages of the operating system

718

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Ab01: Axis bus timeout [xx.0126.00001]

Ab02: Axis bus IO error [xx.0126.00002]

CE04: MCI communication error [xx.0127.00002]

CE0F: MCI control word [xx.0127.00015]

Response (Lenze setting printed in bold)

Setting:

C00591/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The

axis bus data error monitoring

has been triggered as

the monitoring time for data errors set in

C02431/3

has

been exceeded.

• The current number of incorrectly transmitted

telegrams is displayed in

C02438/1

.

• The current number of incorrectly received telegrams

is displayed in

C02438/2

.

• The current axis bus error status is displayed in

C02436

.

• Check wiring and bus terminating resistor.

• Assign different IDs to nodes.

• Eliminate electrical interference (e.g. EMC).

Response (Lenze setting printed in bold)

Setting:

C00591/2

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

An axis bus node has put the

IO axis bus

into the "error"

status with parameterised "master/slave" function

("release cord" principle).

• In the "Error" status, all nodes start their adjustable

response, e.g. a synchronised braking of the drive

system or the master only brakes the network to

standstill.

Remove the fault of the node which pulled the "release

cord".

Note: The "error" status can only be reset by the node

defined as "master".

Response (Lenze setting printed in bold)

Setting:

C01501/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Communication error with extension module in slot 1.

• Eliminate EMC interference.

• Switch off controller, correctly plug in the module,

switch on the controller again.

• Mains switching or restart of the controller,

respectively.

• Replace module/controller.

• Please contact Lenze if the problem occurs again.

Response (Lenze setting printed in bold)

Setting:

C00594/2

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Bit 14 ("SetFail") of the wMciCtrl control word of the

LS_DriveInterface

system block has been set.

Trace back signal source on the bus (e.g. PROFIBUS) that

sets bit 14 ("SetFail").

Advertising