1 resolver/multi-encoder open-circuit monitoring, Resolver/multi-encoder open-circuit monitoring, 6encoder/feedback system – Lenze 8400 TopLine User Manual

Page 369: Danger

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

369

6

Encoder/feedback system

6.7

Monitoring

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.7.1

Resolver/multi-encoder open-circuit monitoring

In the Lenze setting, the resolver cable and/or encoder cable are monitored with regard to open

circuit as a function of the selected speed and position encoder.

Tip!
We recommend the Lenze setting "0: Speed sensor and position encoder" for open-circuit

monitoring (

C00498

). Further possible settings make sense if the respective encoder is not

used as speed sensor or position encoder but for other tasks in the application. Moreover,

a selective switch-off of the monitoring is possible if other settings are made.

When does the open-circuit monitoring system respond?

Response to open circuit

Danger!

• For safety reasons, always select "Fault" (Lenze setting) as a response for the (open-

circuit) monitoring of the resolver/encoder!

• To avoid interference when using an encoder, only use shielded motor and encoder

cables!

Open-circuit monitoring

(

C00498

)

Function

0: Speed encoder and position

encoder

(Lenze setting)

Open-circuit monitoring is active for the speed encoder selected in

C00495

and the position encoder selected in

C00490

.

• Depending on whether a speed encoder or position encoder has been

selected, the monitoring mode for the resolver and/or encoder is

activated.

• If no speed encoder and position encoder have been selected, open-

circuit monitoring is deactivated.

1: Resolver only

Open-circuit monitoring is only active for the resolver, independent on the

selection of the speed encoder and position encoder.

• Open-circuit monitoring for the encoder is deactivated.

2: Encoder only

Open-circuit monitoring is only active for the encoder, independent on the

selection of the speed encoder and position encoder.

• Open-circuit monitoring for the resolver is deactivated.

3: Resolver and encoder

Open-circuit monitoring is active for the resolver and encoder, independent

on the selection of the speed encoder and position encoder.

Resolver

Multi encoder

• In case of open circuit in the encoder cable.

• If the resolver impedance is too high.

• In case of EMC interferences.

• In case of open circuit in the encoder cable.

Resolver

Multi encoder

The error response set in

C00603/2

is triggered (Lenze

setting: "0: No Reaction").

Logbook entry: "

Sd2: Open circuit - resolver

"

The error response set in

C00603/1

is triggered (Lenze

setting: "0: No Reaction").

Logbook entry: "

Sd4: Open circuit - MultiEncoder

"