19.1.152

L_PT1_3

This FB filters and delays analog signals.

• Filter time constant T can be set in

C00250/2

.

• The gain is defined with V

p

= 1.

Inputs

Outputs

Parameter

Function

[19-68] Filter time constant T of the first-order delay element

Identifier

Data type

Information/possible settings

nIn_a

INT

Input signal

Identifier

Data type

Value/meaning

nOut

INT

Output signal

Parameter

Possible settings

Info

C00250/2

0

ms

5000 Filter time constant

• The filter is not active with a

setting of "0 ms". The input signal

is passed through one-to-one to

the output.

• Lenze setting: 2000 ms

/B37B