C01206 | mck: mounting direction, C01210 | mck: current positions, C01206/1 – Lenze 8400 TopLine User Manual

Page 1177: C01206/2, C01210/3, C01210/5, C01210/7, C01210/9, C01210/1, C01210/2

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1177

17

Parameter reference

17.2

Parameter list | C01206

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01206

C01210

Parameter | Name:

C01206 | MCK: Mounting direction

Data type: UNSIGNED_8

Index: 23369

d

= 5B49

h

Inversion for mirrored motor and encoder mounting

Machine parameter

Selection list

0 not inverted
1 inverted

Subcodes

Lenze setting

Info

C01206/1

0: Not inverted

Motor mounting direction

• Setting for motor mounting turned by 180°.

C01206/2

0: Not inverted

Position encoder mounting direction

• Setting for position encoder system mounting turned

by 180°.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01210 | MCK: Current positions

Data type: INTEGER_32

Index: 23365

d

= 5B45

h

Display of current position data of the Motion Control Kernel
Display range

(min. value | unit | max. value)

-214748.3647

units

214748.3647

Subcodes

Info

C01210/1

MCK: Feed

• Display of the current feed for positioning profiles as

a relative distance.

C01210/2

MCK: Set position

• Display of the current setpoint position calculated by

the MCK.

C01210/3

MCK: Actual position

• Display of the current actual position calculated by an

optional encoder system.

C01210/4

MCK: Following error

• Display of the current following error as a difference

between setpoint position and actual position.

C01210/5

MCK: Positioning accuracy

• Display of the current positioning accuracy referred to

the actual number of increments of the position

encoder.

C01210/6

MCK: Target position

C01210/7

MCK: Set position modulo

C01210/8

MCK: Actual position modulo

From version 12.00.00

C01210/9

MCK: Dist. ref. mark and Ref-TP

From version 14.00.00

• Display of the distance between pre-stop mark/limit

switch and TP/MP while homing.

Distance measurement

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Advertising