C01455 | l_sequencer_1: word signal, C01460 | l_convactpos: tconst, C01461 | l_convactpos: maxpos/minpos – Lenze 8400 TopLine User Manual

Page 1225: 17 parameter reference

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1225

17

Parameter reference

17.2

Parameter list | C01455

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01455

C01460

C01461

Parameter | Name:

C01455 | L_Sequencer_1: Word signal

Data type: UNSIGNED_16

Index: 23120

d

= 5A50

h

From version 12.00.00

L_Sequencer_1 (sequence control)

Display range

(min. value | unit | max. value)

0

65535

Subcodes

Info

C01455/1

L_Sequencer_1

: wStartStep

C01455/2

L_Sequencer_1

: wBranch1

C01455/3

L_Sequencer_1

: wBranch2

C01455/4

L_Sequencer_1

: wDigitalInputs

C01455/5

L_Sequencer_1

: wMotionState1

C01455/6

L_Sequencer_1

: wMotionState2

C01455/7

L_Sequencer_1

: wMckPosCtrl1

C01455/8

L_Sequencer_1

: wMckPosCtrl2

C01455/9

L_Sequencer_1

: wAuxCtrl

C01455/10

L_Sequencer_1

: wState

C01455/11

L_Sequencer_1

: wActStep

C01455/12

L_Sequencer_1

: wDigitalOutputs

C01455/13

L_Sequencer_1

: wProfileNumber

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01460 | L_ConvActPos: TConst

Data type: UNSIGNED_16

Index: 23115

d

= 5A4B

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

0

ms

1000

Subcodes

Lenze setting

Info

C01460/1

10 ms

L_ConvActPos_1

: TConst

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01461 | L_ConvActPos: MaxPos/MinPos

Data type: INTEGER_16

Index: 23114

d

= 5A4A

h

From version 12.00.00

Setting range

(min. value | unit | max. value)

-199.99

%

199.99

Subcodes

Lenze setting

Info

C01461/1

100.00 %

L_ConvActPos_1

: MaxPos

C01461/2

-100.00 %

L_ConvActPos_1

: MinPos

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Advertising