1 signal adaptation by means of characteristic, Signal adaptation by means of characteristic, 7i/o terminals – Lenze 8400 TopLine User Manual

Page 406

Advertising
background image

7

I/O terminals

7.3

Analog terminals

406

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.3.1.1

Signal adaptation by means of characteristic

According to the illustration below, an individual characteristic can be parameterised for the analog

inputs via the subcodes of

C00010

and

C00020

to provide different slopes and a dead band. Here,

the input signal corresponds to the X axis and the output signal corresponds to the Y axis:

[7-5]

Characteristic for analog inputs

In the »Engineer«, there is a parameterising dialog for entering the characteristic. This dialog also

displays the set characteristic graphically.

199.99 %

Œ

“



Ž





‘

’

y

max

-y

max

-x

max

x

max

y

min

-y

min

199.99 %

-199.99 %

-199.99 %

Parameter

Info

Lenze setting

Value Unit

C00010/1

AIN1: (+y0) = min

0.00 %

C00010/2

AIN1: (+x0) = Dead band

1.00 %

C00010/3

AIN1: (-y0) = (-min)

0.00 %

C00010/4

AIN1: (-x0) = (-Dead band)

1.00 %

C00010/5

AIN1: (+ymax)

199.99 %

C00010/6

AIN1: (+xmax)

199.99 %

C00010/7

AIN1: (-ymax)

199.99 %

C00010/8

AIN1: (-xmax)

199.99 %

C00020/1

AIN2: (+y0) = min

0.00 %

C00020/2

AIN2: (+x0) = Dead band

1.00 %

C00020/3

AIN2: (-y0) = (-min)

0.00 %

C00020/4

AIN2: (-x0) = (-Dead band)

1.00 %

C00020/5

AIN2: (+ymax)

199.99 %

C00020/6

AIN2: (+xmax)

199.99 %

C00020/7

AIN2: (-ymax)

199.99 %

C00020/8

AIN2: (-xmax)

199.99 %

Advertising