C00654

C00658

C00659

C00660

Parameter | Name:

C00654 | Source of diff. setpoint feedforward control

Data type: UNSIGNED_8

Index: 23921

d

= 5D71

h

From version 12.00.00

Selection of the process signal for the setpoint feedforward control
Selection list

Info

0 nSpeedSetValue_a
1 nSpeedSetValueInertia_a

The new process signal nSpeedSetValueInertia_a at

SB

LS_MotorInterface

can be used to define any input

value (e.g. position or process controller setpoint) for

torque feedforward control.

Subcodes

Lenze setting

Info

C00654/1

0: nSpeedSetValue_a

Source of diff. setpoint feedforward control

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00658 | PRBS amplitude

Data type: INTEGER_16

Index: 23917

d

= 5D6D

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00659 | PRBS duration

Data type: UNSIGNED_16

Index: 23916

d

= 5D6C

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00660 | L_FixSet_a_1: Analog values

Data type: INTEGER_16

Index: 23915

d

= 5D6B

h

FB

L_FixSet_a_1

: Setting of the fixed values

Setting range

(min. value | unit | max. value)

-199.99

%

199.99

Subcodes

Lenze setting

Info

C00660/1

0.00 %

Fixed value 0 ... 15

C00660/...
C00660/16

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100