178 l_transient_6, 178 l_transient_6 5, L_transient_6 – Lenze 8400 TopLine User Manual
Page 1695: 19 function library
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
1695
19
Function library
19.1
Function blocks
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
19.1.178
L_Transient_6
This FB serves to evaluate digital signal edges and convert them into timed, retriggerable pulses.
Rising signal edges, falling signal edges or both signal edges can be evaluated.
Inputs
Outputs
Parameter
Identifier
Data type
Information/possible settings
bIn
BOOL
Input for edge evaluation
• The function depends on the selection of edge evaluation in
Identifier
Data type
Value/meaning
bOut
BOOL
Output (retriggerable)
Parameter
Possible settings
Info
Function
• Selection of edge evaluation
0 High edge
Lenze setting
1 Low edge
2 High and low edge
0.001
s
60.000 Pulse duration
• Lenze setting: 0.001 s
For a detailed functional description see
.
E2XW
E,Q
W
&
&
/B
B
7UDQVLHQW