Encoder - angular drift monitoring

This function extension is available from version 12.00.00!

The encoder angular drift monitoring monitors a possible deviation of the real encoder angle from

the angle calculated by counting increments in the encoder evaluation.

• If a deviation higher than 45° (electrical) is recognised when monitoring is activated:

• The error response set in

C00603/3

is triggered.

• The "

Sd8: Encoder angular drift monit.

" error message is entered into the logbook.

• The "Reference known" status of the "Homing" basic drive function is reset (if this status was

set before)

Tip!
A deviation may occur, for instance, by incorrect parameter setting of the encoder

increments, by lines in the form of interferences caused by EMC or loss of lines caused by

EMC.

Functional principle
For an encoder without absolute information, the number of incoming encoder lines between two

zero pulses (one revolution) is monitored. This value must equal the encoder increments set in

C00420/3

.

Note!

The encoder angular drift monitoring is implemented for encoders without absolute

information.
In the Lenze setting (

C00603/3

= "0: No response"), the angular drift monitoring of the

encoder is not activated!

Note!

After mains switching, monitoring is only active after second incoming zero pulse since

the first line difference to be used can only be calculated with the second and first zero

pulse.
When the motor (and thus the encoder) is replaced, it is very likely that a angular drift

error occurs within the first revolution after acknowledging the encoder error since the

monitoring function cannot recognise that the encoder has been replaced.
Due to the type of monitoring, accuracy (distance of Z pulse to the detected position) can

only be detected while the machine is running. As a permanently pending error would

prevent the error cause to be removed, a detected error will be automatically reset by the

controller after a short time. In order that the motor does not continue to rotate in this

case, an engaging error response (e.g. "Fault" or "TroubleQSP") has to be set. If an error is

detected again, it is entered again into the logbook.