C01416 | l_sequencer_1: branchlevel, C01417 | l_sequencer_1: branchstep, C01418 | l_sequencer_1: branchstep1 – Lenze 8400 TopLine User Manual

Page 1212: 17 parameter reference

Advertising
background image

17

Parameter reference

17.2

Parameter list | C01416

1212

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01416

C01417

C01418

Parameter | Name:

C01416 | L_Sequencer_1: BranchLevel

Data type: UNSIGNED_8

Index: 23159

d

= 5A77

h

From version 12.00.00

L_Sequencer_1: "Branch" action

Setting range

(min. value | unit | max. value)

0

1

Subcodes

Lenze setting

Info

C01416/1

0

L_Sequencer_1

: Branch act. 1: Input polarity

C01416/...

...

C01416/16

L_Sequencer_1

: Branch act. 16: Input polarity

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01417 | L_Sequencer_1: BranchStep

Data type: UNSIGNED_16

Index: 23158

d

= 5A76

h

From version 12.00.00

L_Sequencer_1: "Branch" action

Setting range

(min. value | unit | max. value)

0

100

Subcodes

Lenze setting

Info

C01417/1

0

L_Sequencer_1

: Branch act.1: Jump destination

C01417/...

...

C01417/16

L_Sequencer_1

: Branch act. 16: Jump destination

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01418 | L_Sequencer_1: BranchStep1

Data type: UNSIGNED_16

Index: 23157

d

= 5A75

h

From version 12.00.00

L_Sequencer_1: "Variable branch" action

Setting range

(min. value | unit | max. value)

0

100

Subcodes

Lenze setting

Info

C01418/1

0

L_Sequencer_1

: Var. branch 1: Jump destin. 1

C01418/2

0

L_Sequencer_1

: Var. branch 2: Jump destin. 1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1