6encoder/feedback system – Lenze 8400 TopLine User Manual

Page 344

Advertising
background image

6

Encoder/feedback system

6.3

Multi-Encoder (X8)

344

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Scaling of the position value
In order to scale the position change provided by the position encoder at this feed to 65536 as well,

enter the traverse path in [units] in

C1111/1

and the corresponding difference of the raw value

provided by the encoder in

C1111/2

.

• Only the bits that contain the position data may be taken from the data word for the raw value.

If e.g. the bit 0 contains status information, the raw value must be shifted to the right by this bit

since only then the SLB of the position value is positioned correctly.

Example for scaling
1 [unit] = 1 mm
Feed constant (

C01204

) = 4 mm/revolution

Encoder resolution = 50 μm  raw value difference = 20 [digit]/1 [unit]

Difference - traverse path (

C1111/1

) = 1 [unit]

Difference - encoder value (

C1111/2

) = 20 [digit]

Thus, at a feed of the mechanics of 4 mm, the encoder provides a position difference of 65536

increments.

Position

Raw value Encoder feed constant

65536

---------------------------------------------------------

=

with encoder feed constant

C01111/1 65536

2

C01111/2 C01204

--------------------------------------------------

=

Position

Raw value C01111/1 65536

C01111/2 C01204

--------------------------------------------------

=

Advertising