C01040 | l_srfg_1 linear ramp time, C01041 | l_srfg_1 s-ramp time, C01042 | l_srfg_1 limitations of output values – Lenze 8400 TopLine User Manual

Page 1144: 17 parameter reference

Advertising
background image

17

Parameter reference

17.2

Parameter list | C01040

1144

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01040

C01041

C01042

Parameter | Name:

C01040 | L_SRFG_1..2 linear ramp time

Data type: UNSIGNED_32

Index: 23535

d

= 5BEF

h

Symmetrical acceleration/deceleration time for the ramp function generator
Setting range

(min. value | unit | max. value)

0.001

s

999.999

Subcodes

Lenze setting

Info

C01040/1

100.000 s

L_SRFG_1

: linear ramp time

C01040/2

100.000 s

L_SRFG_2

: linear ramp time

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01041 | L_SRFG_1..2 S-ramp time

Data type: UNSIGNED_32

Index: 23534

d

= 5BEE

h

S-ramp time for jerk-free acceleration
Setting range

(min. value | unit | max. value)

0.001

s

50.000

Subcodes

Lenze setting

Info

C01041/1

0.200 s

L_SRFG_1

: S-ramp time

C01041/2

0.200 s

L_SRFG_2

: S-ramp time

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01042 | L_SRFG_1..2 limitations of output values

Data type: INTEGER_16

Index: 23533

d

= 5BED

h

Limitation of the output values
Setting range

(min. value | unit | max. value)

-199.99

%

199.99

Subcodes

Lenze setting

Info

C01042/1

100.00 %

L_SRFG_1

: Pos. Limit

C01042/2

-100.00 %

L_SRFG_1

: Neg. Limit

C01042/3

100.00 %

L_SRFG_2

: Pos. Limit

C01042/4

-100.00 %

L_SRFG_2

: Neg. Limit

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100