Function library

19.1

Function blocks

1664

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

19.1.158.14 "Stand-by" action type

For a temporary activation of a setpoint follower, 5 actions of "stand-by" type are available.

• The corresponding setpoint follower remains enabled until the condition for completing stand-

by is fulfilled.

• If the "stand-by" step is active, the setpoint set in

C01452

is provided at the nSet_a output

(Lenze setting: 0 %) .

Action call (entry in the sequence table)

with action number xxx = 001 ... 005

Parameter
The available actions 1 ... 5 are represented via the subcodes 1 ... 5.

Parameter

Possible settings

Info

C01449/1...5

Stand-by act. n: Input for "End"

• The setpoint follower selected in

C01451/x

remains enabled until

the sequencer input selected here

has the polarity set in

C01450/x

.

1 Sequencer input 1

(Bit 0 of wDigitalInputs)

2 Sequencer input 2

(Bit 1 of wDigitalInputs)

... ...

16 Sequencer input 16

(Bit 15 of wDigitalInputs)

C01450/1...5

Stand-by act. n: Polarity input

• State of the selected sequencer

input required for ending the

stand-by an processing the

sequence step.

0 Condition is bit state "0"
1 Condition is bit state "1"

C01451/1...5

Stand-by act. n: Follower mode

• Selection which follower in the

stand-by mode is to be activated.

0 Operation

Speed follower

1 Operation

Position follower

C01452/1...5

-200

%

200 Stand-by act. n: Setpoint

• Setpoint for the

Speed follower

(provided at the output nSet_a).

• Initialisation: 0 %

Standby

1 0 x x x